1 sk tu1- cannord / canopen module, overview, 2 cannord module, sk tu1-can, Sk tu1- cannord / canopen module, overview – NORD Drivesystems BU0060 User Manual

Page 23: Cannord module, sk tu1-can, 2 modules

Advertising
background image

2 Modules

BU 0060 GB-4112

23

2.2.1 SK TU1- CANnord / CANopen module, overview

The communication modules SK TU1-CAN bor SK TU1-CAO are used to connect drive units of the SK
700E series to higher level automation systems via CANnord or CANopen.

Module

Description

Data

CANnord module
SK TU1-CAN

This option enables control of the SK 700E via the CAN
serial port.

1 CANnord interface
Connector: Sub-D9
Part No. 278200070

CANopen module
SK TU1-CAO

This option enables control of the SK 700E via the
CANopen serial port.

1 CANopen interface
Connector: Sub-D9
Part No. 278200075

Table 4: SK TU1-CAN / -CAO, overview of technology units

Pos : 40 /Anl eitungen/ Elektroni k/ Bus s yst eme/2. Baugruppen/CAN open [BU 0060]/C AN nor d M odul, SK TU1-C AN @ 1\ mod_1341830232485_388.doc x @ 30405 @ 3 @ 1

2.2.2 CANnord module, SK TU1-CAN

The CANnord interface on NORD
frequency inverters enables
parameterisation and control of
devices as per the CAN
specifications 2.0A and 2.0B. Up
to 110 nodes can be addressed
on a single Bus. Termination
resistors are integrated and can
be switched in.

The transfer rate can be set to
between 10 kBit and 500 Kbit/s.

The conflict and error recognition
integrated in the CANnord
protocol enables maximum Bus
usage and data security.

1

CANnord Status LEDs

TxD

(green)

Transmitting CAN

data

RxD

(green)

Receiving CAN data

2

Termination resistor



(ON)

Connected



(OFF)

Not connected

3

SUB – D9

GND

CAN_L

6

1

5

9

GND

CAN_H

Pos : 41 /Anl eitungen/ Elektroni k/ Bus s yst eme/2. Baugruppen/CAN open [BU 0060]/C AN open Modul, SK TU1-C AO @ 1\ mod_1341836350786_388. doc x @ 30480 @ 3 @ 1