2.2.4 Installation of the SK TU1 technology unit

WARNING

Electric shock

Modules must not be inserted or removed unless the device is free of voltage. The slots may only be used for
the intended modules. Installation remote from the frequency inverter is not possible. It must be connected
directly to the frequency inverter.

Failure to comply with this may result in an electric shock, which my cause serious injury and the destruction of
the frequency inverter and the module.

Installation of the technology units must be carried out as follows:

1.

Switch off the mains voltage, observe the waiting period.

2.

Remove the dummy cover by actuating the unlocking device on the top and bottom edge.

3.

Press the technology unit onto the mounting surface, until it audibly engages.