CANopen – Supplementary manual options for NORD - Frequency Inverters

86

BU 0060 GB-4112

5.2.3 Information

Parameter

Setting value / Description / Note

Supervisor

Parameter set

Pos : 162 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P707 – Soft ware- Versi on/-Revisi on @ 0\ mod_1328171743458_388. doc x @ 12479 @ @ 1

P707

[-01]

...

[-03]

Software-Version

(Software version/ revision)

0.0 ... 9999.9

This parameter shows the software and revision
numbers in the FI. This can be significant when
different FIs are assigned the same settings.

Array 03 provides information about any special
versions of the hardware or software A zero
stands for the standard version.

... ... [-01] = Version number (1.7)

... ... [-02] = Revision number (R0)

... ... [-03] = Special version of

hardware/software (0.0)

Pos : 163 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P740 – Prozes sdat en Bus In [ SK 500... 535E] @ 0\ mod_1328175248086_388. doc x @ 13313 @ @ 1

P740

[-01]

...

[-13]

Process Data Bus In

(Process data Bus In)

S

0000 ... FFFF (hex)

This parameter informs
about the actual control
word and the setpoints that
are transferred via the bus
systems.

For display, a BUS system
must be selected in P509

[-01 ] = Control word

Control word, source from
P509.

[-02] = setpoint value 1
[-03] = setpoint value 2
[-04] = setpoint value 3

Setpoint data from main
setpoint (P510 [-01]).

[-05] = Bus I/O In Bits (P480)

The displayed value depicts all
Bus In Bit sources linked with
"OR".

[-06] = Parameter data In 1
[-07] = Parameter data In 2
[-08] = Parameter data In 3
[-09] = Parameter data In 4
[-10] = Parameter data In 5

Data during parameter transfer:
Order label (AK),Parameter
number (PNU), Index (IND),
Parameter value (PWE 1/2)

[-11] = setpoint value 1
[-12] = setpoint value 2
[-13] = setpoint value 3

Setpoint data from the master
function value (Broadcast), if
P509 = 9/10
(P510 [-02])

Pos : 164 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P740 – Prozes sdat en Bus In [ SK 54xE] @ 0\ mod_1328177837899_388.doc x @ 13336 @ @ 1