13.52 Setting Insertion of Infrared Cut Filter

Camera Control Command Type 2

Function

Sets the status when infrared cut filter is inserted.

Command

00B5h

Parameter length

1 byte.

Parameter

Parameter value

1h

Status

None

Reference

•Once this command is received, the filter insertion process and the built-in
infrared light LED OFF process are both performed simultaneously.

Format of Control Code

d0 d1

d2 d3 d4 d5

d6

Header Device

Num Command Parameter

End

mark

FFh 30h

3Xh

00h B5h 31h

EFh

Answer Format

d0 d1

d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h

3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
No Error :

00000000B

⇒ 00h ⇒ 30h 30h

Busy :

00010000B

⇒ 10h ⇒ 31h 30h

Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Conditions for setting of error flag

Busy

•Filter insertion/removal operation is in progress.

Parameter Error •The designated parameter is an invalid value.
Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.
•This command was received while filter was inserted.


Advertising