Vaddio Canon VC-C50i Programmers User Manual

Page 159

Advertising
background image

158

14.27

Cascade

OFF

System Control Command Type 1

Function

To release Cascade Connection OFF.

Command 008Fh

Length 1

byte

Parameter

Value 0h

Status None
Reference •Cascade connection status comes out OFF by default at the moment of

power ON.
•Multiple VC-C50i's unable to control in status of cascade OFF.
•Device number of this command is only "3030h"
•Usable device number in cascade OFF, is only "3030h"
Cascade ON/OFF commands are effective for all VC-C50i connected even
in a cascade OFF status.
•To force to stop Pan/Tilt operation by this command except operating
pedestal initialize.
•Necessary to issue this command before issuing Cascade ON
command (14.28).

Format of Control Code

d0 d1 d2 d3 d4 d5

d6

Header Device

Num

Command Parameter

End

mark

FFh 30h 30h 00h 8Fh 30h

EFh

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 30h e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Mode Error

•In case of operating MENU by Local Mode.

Advertising