12.26 Pan/Tilt Angle Request

Pedestal Control Command Type 1

Function

To request angle (position) in Pan/Tilt direction.

Command 0063h
Parameter None

Length

8 byte (Pan angle: 4 bytes, tilt angle: 4 bytes)

Status

Range

Within range of Pan and Tilt Movable Range

Reference •Parameter value (1LSB) of both Pan/Tilt is equal to approx. 0.1125 by

converting to angle. (see 12.17 and 12.18)
•Status section (8 byte) splits s0~s3 as Pan (position) section, and s4~s7
as Tilt (position) section.
•The value of each status is indicated as angle at Home Position (8000h)
(See 12.25 Pan/Tilt Angle Assignment.)
•This command returns the angle (position), at the moment of receipt of
Command even though Pan/Tilt is in action except executing Pedestal
Initialize 1 & 2
.

Note : After power ON, in case of receipt of this command without executing

Pedestal Initialize 1 & 2, return mode error.

Format of Control Code

d0 d1 d2 d3 d4 d5

Header Device

Num

Command End

mark

FFh 30h 3Xh 00h 63h EFh

Answer Format
In case of No Error

d0 d1 d2 d3 d4

Header

Device Num

Error Code

EFh 30h 3Xh 30h 30h

d5 d6 d7 d8 d9 d10 d11

d12 d13

Pan Angel Status

Tilt Angle Status

End mark

s0 s1 s2 s3 s4 s5 s6 s7 EFh

The present position indicates in hexadecimal 8 figures and its ASCII is as parameter
value.
Example: Pan right 90 degrees

Tilt lower 30 degrees

Pan

s0

s1

s2

s3

+800

⇒ 8320h

⇒ 38h 33h 32h 30h

Tilt

s4

s5

s6

s7

–267

⇒ 7EF5h

⇒ 37h 45h 46h 35h