Vaddio Canon VC-C50i Programmers User Manual

Page 116

Advertising
background image

115

13.53 Settings when Infrared Cut Filter Not Inserted

Camera Control Command Type 2

Function

Sets the status when infrared cut filter is not inserted.

Command

00B5h

Length

1 byte.

Parameter

Value

0h

Status

None

Reference

Format of Control Code

d0 d1 d2 d3 d4 d5

d6

Header Device

Num Command Parameter

End

mark

FFh 30h

3Xh 00h B5h 30h

EFh

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Busy :

00010000B

⇒ 10h ⇒ 31h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Busy

•Filter insertion/removal operation is in progress

Parameter Error •In case of assigned parameter illegal
Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.
•This command was received while filter was inserted.

Advertising