Unit and 5, Byte 4 – Vaddio Canon VC-C50i Programmers User Manual

Page 15

Advertising
background image

14

Note 4 : The details of the communication timing are referring to 3.3 Communication Timing

Diagram.

7.2 Format of Cascade Global Notification Data
Before the time to terminate the execution, the data format from VC-C50i to the computer is
configured as shown below.

Header Device

Num Notification

Code End

mark

Header

: 1 byte F8h

Device Num

: 2 byte 3031h~3039h (Last device number connected in cascade.)

Notification Code : 4 byte Present information of VC-C50i connected.
End mark

: 1 byte EFh


7.3 Notification Code
The error information of VC-C50i connected in cascade indicates in hexadecimal, returns its
ASCII code. If the error does not exists, all bits of notification flags will be cleared and become
zero.

• Bit Assignment of Error Flags.

b15(MSB) b14 b13 b12 b11 b10 b9 b8

System Resv.(0)

System Resv.(0)

System Resv.(0)

System Resv.(0)

System Resv.(0)

System Resv.(0)

System Resv.(0)

Cascade 9

th

b7 b6 b5 b4 b3 b2 b1 b0(LSB)

Cascade 8

th

Cascade

7

th

Cascade

6

th

Cascade

5

th

Cascade

4

th

Cascade

3

rd

Cascade

2

nd

Cascade

1

st


Example: 6 units are connected in cascade, and the errors occur in 1

st

unit and 5

th

unit.


1st byte 2nd byte
b15 = 0, b14 = 0, b13 = 0, b12 = 0 b11 = 0, b10 = 0, b9 = 0, b8 = 0
0h

30h 0h

30h

(Hexadecimal indication

ASCII code conversion)


3

rd

byte 4

th

byte

b7 = 0, b6 = 0, b5 = 0, b4 = 1 b3 = 0, b2 = 0, b1 = 0, b0 = 1
1h

31h 1h

31h

(Hexadecimal indication

ASCII code conversion)



Example of Notification data

d0 d1 d2 d3 d4 d5 d6 d7

Header Device

Num

Notification

Code

End

mark

F8h 30h 36h 30h 30h 31h 31h EFh


Advertising