Vaddio Canon VC-C50i Programmers User Manual

Page 55

Advertising
background image

54

12.27 Pan Movable Range Assignment

Pedestal Control Command Type 1

Function

To assign movable range in Pan direction.

Command 0064h

Length 9

byte

Normal Mounting: –889~+889 (7C87h~8379h)

Parameter

Range

Inverse Mounting: –1511~+1511 (7A19h~85E7h)

Status None
Reference •Maximum & minimum (position) movable angle can be set, when Pan motion

command is set by Pan Right Start and Pan Left Start are executed.
•To set Pan maximum & minimum angle (position) which can be set by
Pan/Tilt Angle Assignment command.
•Parameter value (1LSB) of Pan is equal to approx. 0.1125 by converting to
angle. (see 12.17)
•Minimum parameter value can be obtained by Pan Minimum Angle
Request
command (12.19) and maximum value can be obtained by Pan
Maximum Angle Request
(12.20).
•Parameter section (9byte) splits minimum angle (position) as p1~p4 and
maximum angle (position) as p5~p8.
•Minimum & maximum Pan parameter value is to set at angle of Home
Position
(8000h). See 12.25 Pan/Tilt Angle Assignment
•Not necessary to include Home Position between minimum and maximum
angle (position). But minimum angle value must set equal or less value of
maximum value.
•When Pedestal Initialize 1 command executes, move to Home Position, even
though out of range.
•In case that Pan position is out of range before executing Pedestal Initialize 2
command, it return to minimum or maximum position within motion range
by the return motion.

Format of Control Code

d0 d1 d2 d3 d4

Header Device

Num

Command

FFh 30h 3Xh 00h 64h

d5 d6 d7 d8 d9 d10 d11 d12

d13 d14

Fixed

Minimum Angle Parameter

Maximum Angle Parameter

End mark

30h p1 p2 p3 p4 p5 p6 p7 p8 EFh

Running speed indicates in hexadecimal 8 figures and returns ASCII as parameter value.
Example: Min Value (left) 90 degrees, Max Value (right) 45 degrees
p1

p2

p3

p4

Left –800

⇒ 7CE0h

⇒ 37h 43h 45h 30h

p5

p6

p7

p8

Right +400

⇒ 8190h

⇒ 38h 31h 39h 30h


Advertising