Vaddio Canon VC-C50i Programmers User Manual

Page 97

Advertising
background image

96

13.35 AGC Gain Request

Camera Control Command Type 1

Function

To return present AGC gain.

Command

00A5h

Length

1 byte

Parameter

Value

8h

Length 2

byte

Status

Range 00h~FFh

Reference

Format of Control Code

d0 d1 d2 d3 d4 d5 d6

Header Device

Num

Command Parameter End

mark

FFh 30h 3Xh 00h A5h 38h EFh

Answer Format
In case of No Error

d0 d1 d2 d3 d4 d5 d6

d7

Header

Device Num

Error Code

AGC Gain Value

End mark

FEh 30h 3Xh 30h 30h s0 s1

EFh

AGC gain value indicates in hexadecimal 2 figures and its ASCII code is Status value.
Example: s0

s1

10

⇒ 0Ah

⇒ 30h 41h

In case of Error

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of Busy :

00010000B

⇒ 10h ⇒ 31h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Busy

•In process of camera initializing operation by Camera Reset
command, etc.
•In case of executing Preset Move command.

Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.

Advertising