14.8 Internal Infrared Light Status Request

System Control Command Type 1

Function

Returns the internal infrared light ON/OFF setting status.

Command 0077h
Parameter

None

Length 1

byte

Status

Value

0h: Internal infrared light OFF
1h: Internal infrared light ON

Reference

Format of Control Code

d0 d1

d2 d3 d4 d5

Header Device

Num Command End

mark

FFh 30h

3Xh

00h 77h EFh

Answer Format
No Error

d0 d1 d2 d3 d4 d5 d6

Header

Device Num

Error Code

Status

End mark

FEh 30h

3Xh

30h 30h s0 EFh

Setting value indicates in hexadecimal 1 figure and its ASCII code is Status value.
s0
Internal infrared light OFF:

0h

⇒ 30h

Internal infrared light ON:

1h

⇒ 31h

Generated Error

d0 d1

d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h

3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Conditions for setting of error flag

Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.




Advertising