13.54 Infrared Cut Filter Status Request

Camera Control Command Type 1

Function

Returns the setting status of the infrared cut filter.

Command

00B6h

Parameter

None

Length 1

byte

Filter inserted status : 1h

Status

Value

Filter not inserted status : 0h

Under the Filter movement : 2h

Reference •Infrared cut filter status is returned as a one-digit hexadecimal number.

Format of Control Code

d0 d1 d2 d3 d4 d5

Header Device

Num Command End

mark

FFh 30h

3Xh 00h B6h EFh

Answer Format
No Error

d0 d1 d2 d3 d4 d5 d6

Header

Device Num

Error Code

Status

End mark

FEh 30h 3Xh 30h 30h s0 EFh

The setting value is expressed as a one-digit hexadecimal number with the ASCII
code as a status value.
s0
Inserted status:

1h

⇒ 31h

Not inserted status:

0h

⇒ 30h

Generated Error

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value
Example: e0 e1
In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Mode Error

•Not in status of Camera ON
•Not in status of Host Control Mode

Advertising