12.21 Tilt Minimum Angle Request

Pedestal Control Command Type 1

Function

To return the minimum value (down) in Tilt direction.

Command 005Ch

Length 1

byte

Parameter

Value 2h
Length 4

byte

Normal Mounting: –267 (7EF5h)

Status

Value

Inverse Mounting: –800 (7CE0h)

Reference •Status Value (-267) in normal mounting is the position rotated approx.

30 degree to down as zero degree for horizontal.
•Status Value (-800) in inverse mounting is the position rotated approx.
90 degrees to down as zero degree for horizontal.

Format of Control Code

d0 d1 d2 d3 d4 d5 d6

Header Device

Num

Command Parameter End

mark

FFh 30h 3Xh 00h 5Ch 32h EFh

Answer Format
In case of No Error

d0 d1 d2 d3 d4 d5 d6 d7 d8 d9

Header

Device Num

Error Code

Status

End mark

FEh 30h 3Xh 30h 30h 37h 45h 46h 35h EFh

or

d0 d1 d2 d3 d4 d5 d6 d7 d8 d9

Header

Device Num

Error Code

Status

End mark

FEh 30h 3Xh 30h 30h 37h 43h 45h 30h EFh

In case of Error

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Parameter Error •Assign illegal parameters.