Vaddio Canon VC-C50i Programmers User Manual

Page 174

Advertising
background image

173

14.39 Default Setting

System Control Command Type 1

Function

To initialize in status of factory setting.

Command

0093h

Length 1

byte

Parameter

Value 0h

Status

None

Reference •To return to status of factory setting at shipping from factory.

(to re-write memory data of built in nonvolatile IC)
•By this command, all items except the followings reset default values at the
shipping status from factory.
•Pedestal

Initial

Information

•Date,

Time

setting

•Indication

Character

setting

•By this command, camera section is rest.
•By this command, communication section with host is reinitialized.
(Baud rate: 9600 bps, stop: 1 bit)
•Host Control Mode unchanged, but cascade OFF status comes out.
•By this command, CTS signal of host stop one second OFF.
Note:
•Necessary to issue another commands after two seconds passed from issuing
this command.

Format of Control Code

d0 d1 d2 d3 d4 d5

d6

Header Device

Num

Command Parameter

End

mark

FFh 30h 3Xh 00h 93h 30h

EFh

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Busy :

00010000B

⇒ 10h ⇒ 31h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Busy

•In case of executing of Camera Control command.
•In case of executing Pedestal Control command.
•In case of executing Preset Move command.

Parameter Error •In case of assigned parameter except 0h.
Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.

Advertising