Vaddio Canon VC-C50i Programmers User Manual

Page 33

Advertising
background image

32

12.8 Tilt Up Start

Pedestal

Control

Command

Type

2

Function

To start Tilt running to the up.

Command 0053h

Length 1

byte

Parameter

Value 3h

Status None
Reference •Until

Pan/Tilt Stop command issues, or reaches to the upper limit, continue

to run.
•The running speed is able to set by Tilt Speed Assignment command.
•By issuing this command, 1 is set in Tilt running flag among the running
status.
The setting flag will be done, just before running pedestal. When pedestal
reaches to the upper limit, Tilt running will stop and clear Tilt Running flag
and 1 of Tilt Limit Position will be set.
Note: After power ON, at the moment of receipt of this command without

executing Pedestal Initialize 1 or Pedestal Initialize 2, returns mode
error and executes Pedestal Initialize 2.

Format of Control Code

d0 d1 d2 d3 d4 d5 d6

Header Device

Num

Command Parameter End

mark

FFh 30h 3Xh 00h 53h 33h EFh

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

EFh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Busy :

00010000B

⇒ 10h ⇒ 31h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Busy

•In case of executing Home Position, Pedestal Initialize 1 and
Pedestal Initialize 2 commands.
•In case of executing Pan/Tilt Angle Assignment and Preset
Move
commands.

•Executing Tilt running by Pedestal Control command.

Parameter Error •Assign illegal parameters.
Mode Error

•After turn ON, Pedestal Initialize has never been done.
•Not in status of Camera ON.
•Not in status of Host Control Mode.





Normal Mounting: Up direction Inverse Mounting: Up direction

Advertising