14.7 Internal Infrared Light ON/OFF Control

System Control Command Type1

Function

Sets the internal infrared light ON/OFF control.

Command

0076h

Length 1

byte

Parameter

Value

0h: Internal infrared light OFF
1h: Internal infrared light ON (automatic OFF after 30

minutes)

2h: Internal infrared light ON (automatic OFF after 1 hour)
3h: Internal infrared light ON (automatic OFF after 2 hours)
4h: Internal infrared light ON (automatic OFF after 3 hours)
5h: Internal infrared light ON (automatic OFF after 4 hours)
6h: Internal infrared light ON (automatic OFF after 8 hours)

Status None
Reference •The Light ON command executes the following operations according to the

status.
(1) If a command is received in the Light OFF status, the Light ON Start and

the Automatic OFF Time Set operations are performed.

(2) If a command is received in the Light ON status, the Automatic Off Timer

Counter Reset and the Automatic Off Time Set operations are performed.

•The light cannot be turned on whenever the infrared cut filter is inserted. In
this case, a mode error is returned.

Format of Control Code

d0 d1 d2 d3 d4 d5

d6

Header Device

Num Command Parameter

End

mark

FFh 30h

3Xh 00h 76h p0

EFh

Setting value indicates in hexadecimal 1 figure and its ASCII code is Status value.
Example: p0
Light On (automatic OFF after 30 minutes):

1h

⇒ 31h

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h

3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
No Error :

00000000B

⇒ 00h ⇒ 30h 30h

Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Conditions for setting of error flag

Parameter Error •In case of assigned parameter illegal.
Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.
Infrared Cut Filter is inserted.

Advertising