Vaddio Canon VC-C50i Programmers User Manual

Page 130

Advertising
background image

129

14.3 Alarm Output Status Request

System Control Command Type 1

Function

Returns the alarm output setting status.

Command

0073h

Parameter

None

Length

1 byte :

Status

Value

0h: Alarm output OFF (open)
1h: Alarm output ON (short)

Reference

Format of Control Code

d0 d1

d2 d3 d4 d5

Header Device

Num Command End

mark

FFh 30h

3Xh

00h 73h EFh

Answer Format
No Error

d0 d1

d2 d3 d4 d5 d6

Header

Device Num

Error Code

Status

End mark

FEh 30h

3Xh

30h 30h s0

EFh

The setting value is expressed as a one-digit hexadecimal number with the
ASCII code as the status value.
s0
Alarm Output OFF:

0h

⇒ 30h

Alarm Output ON:

1h

⇒ 31h

Generated Error

d0 d1

d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h

3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
Mode Error : 10010000B

⇒ 90h ⇒ 39h 30h

Conditions for setting of error flag

Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.



Advertising