Vaddio Canon VC-C50i Programmers User Manual

Page 162

Advertising
background image

161

14.30 Local Control Mode

System Control Command Type 1

Function

To set local control mode.

Command

0090h

Length 1

byte

Parameter

Value 1h

Status

None

Reference •At the moment of power ON, default sets Local Control Mode.

•To be controlled by remote control and unable to control by host computer.
•In case that flag of Local Control Mode is set 1 among of operating status,
all commands except the following commands come out to mode error.
Operation Status Request and Extended Operation Status Request
commands.
Cascade ON and Cascade OFF commands
Host Control Mode and Local Control Mode commands

•In case of remote control receipt forbidden by Remote Control OFF
command before issuing this command, remote control operation is
forbidden, even in Local Control Mode status.
•In case of Remote Control Through Function ON by Remote Control
Through Assignment
command before issuing this command, to control by
remote control and notify its information to host computer.

Format of Control Code

d0 d1 d2 d3 d4 d5

d6

Header Device

Num

Command Parameter

End

mark

FFh 30h 3Xh 00h 90h 31h

EFh

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Parameter Error •In case of assigned illegal parameter.
Mode Error

•In case of operating MENU by Local Mode.

Advertising