0086h

Parameter

1h
Length 4

byte

Status

Value

Based on the operation status (16 bit) value indicating the
internal status.

Reference The following statuses are indicated when each bit in the status is 1.

(MSB)

b15

Not used (undetermined value)

b14

Not used (undetermined value)

b13

Not used (undetermined value)

b12

Not used (undetermined value)

b11

Not used (undetermined value)

b10

Not used (undetermined value)

b9

Not used (undetermined value)

b8

Not used (undetermined value)

b7

Displayed on screen (central control)

0: off, 1: on

b6

Displayed as user text

0: off, 1: on

b5, 4

Displayed date b5

b4

0 0 :

off

0 1 :

Displayed

as

style

1

1 0 :

Displayed

as

style

2

b3, 2

Displayed time b3

b2

0 0 :

off

0 1 :

Displayed

as

style

1

1 0 :

Displayed

as

style

2

b1 Date setting completed 0: Not set 1: Setting completed
b0 Time setting completed 0 :Not set 1: Setting completed
(LSB)
•The b0, b1 information is identical to the information in 14-15. Extended
Operation Status Request
(b16, b17).

Format of Control Code

d0 d1

d2

d3 d4 d5

d6

Header Device

Num Command Parameter End

mark

FFh 30h

3Xh

00h 86h 31h

EFh