4. Control Command Format
This format is to transmit from the computer to VC-C50i.

Header Device

Num

Command Parameter End

mark

Header

: 1 byte FFh

Device Num : 2 byte 3030h~3039h (Device number in cascade connection)
Command : 2 byte (refer to 12. Details of Pedestal Control Commands
~ 14. Details of System Control Commands
)
Parameter : Variable length If not specified, parameter manifests hexadecimal, transmits

its ASCII code.

End mark : 1 byte EFh

Just after power on, device number is 3030 and each device number is determined by Cascade
ON
control command.
The control command (Global Command) of device number 3030 became valid to all VC-C50i
connected in Cascade ON status.


5. Answer Format

5.1 Answer Format
This answer format corresponds to the control command transmitted from the computer to
VC-C50i.

Header

Device Num

Error Code

Status

End mark

Header

: 1 byte FEh

Device Num : 2 byte 3030h~3039h (Device number in cascade connection)
Error Code : 2 byte manifested error flag In hexadecimal and return it's ASCII code.
Status

: Variable length If not specified, status manifests hexadecimal, transmits

its ASCII code.
End mark : 1 byte EFh

Under the condition in Cascade Connection ON, the answer corresponding to control
command of device number 3030, is returned only to the last device connected in cascade.

5.2 Error Code
Error code manifests error flag in hexadecimal and returns it’s ASCII code. If not exists error,
all bits of error flags are cleared and becomes zero.

The bit assignment of error flag.

b7(MSB) b6 b5 b4 b3 b2 b1 b0(LSB)

Mode error

Parameter error

Command error

Busy

System

reservation

System

reservation

System

reservation

System error

1st byte

b7: Mode Error

In case of wrong mode

b6: Parameter Error

In case of receiving wrong parameter

b5: Command Error

In case of receiving wrong command

b4: Busy

In case of unable to execute by error