14.26 LED Forced Control

System Control Command Type 1

Function

To control LED forcibly.

Command 008Eh

Length 1

byte

Parameter

Value 1h~4h

Status None
Reference •LED normal display comes out by default at the moment of power ON.

•The followings settings available by parameter.

Parameter Value

1h: Green LED forced ON

2h: All LED forced OFF

3h: Red LED forced ON

4h:

Orange

LED

forced

ON

Format of Control Code

d0 d1 d2 d3 d4 d5

d6

Header Device

Num

Command Parameter

End

mark

FFh 30h 3Xh 00h 8Eh p0

EFh

LED display forced setting indicates in ASCII 1 byte.
Example: All LED forced OFF

p0

2h

⇒ 32h

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Parameter Error •In case of assigned parameter outside 1h ~ 4h.
Mode Error

•Not in status of Host Control Mode.