14.26 LED Forced Control

System Control Command Type 1

Function

To control LED forcibly.

Command 008Eh

Length 1

byte

Parameter

Value 1h~4h

Status None
Reference •LED normal display comes out by default at the moment of power ON.

•The followings settings available by parameter.

Parameter Value

1h: Green LED forced ON

2h: All LED forced OFF

3h: Red LED forced ON

4h:

Orange

LED

forced

ON

Format of Control Code

d0 d1 d2 d3 d4 d5

d6

Header Device

Num

Command Parameter

End

mark

FFh 30h 3Xh 00h 8Eh p0

EFh

⇓

LED display forced setting indicates in ASCII 1 byte.
Example: All LED forced OFF

p0

2h

⇒ 32h

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

⇓

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Parameter Error •In case of assigned parameter outside 1h ~ 4h.
Mode Error

•Not in status of Host Control Mode.