Vaddio Canon VC-C50i Programmers User Manual

Page 60

Advertising
background image

59

12.30 Tilt Movable Range Request

Pedestal Control Command Type 1

Function To

request

movable

range in Tilt direction.

Command 0065h

Length 1

byte

Parameter

Value 1h
Length 8

byte

Normal Mounting: –267 ~ +800 (7EF5h~8320h)

Status

Range

Inverse Mounting: –800 ~ +89 (7CE0h~8059h)

Reference •Parameter value (1LSB) of Tilt is equal to approx. 0.1125 by converting to

angle (see 12.18).
•Parameter section (8byte) splits minimum angle (position) as s0~s3 and
maximum angle (position) as s4~s7.
•Minimum & maximum parameter value is to set at angle of Home Position
(8000h). See 12.28 Tilt Movable Range Assignment.

Format of Control Code

d0 d1 d2 d3 d4 d5 d6

Header Device

Num

Command Parameter End

mark

FFh 30h 3Xh 00h 65h 31h EFh

Answer Format
In case of No Error

d0 d1 d2 d3 d4

Header

Device Num

Error Code

FEh 30h 3Xh 30h 30h

d5 d6 d7 d8 d9 d10 d11

d12 d13

Minimum

Angle

Status Maximum Angle Status

End mark

s0 s1 s2 s3 s4 s5 s6 s7 EFh

Running speed indicates in hexadecimal 8 figures and returns ASCII as parameter value.
Example: Min Value (lower) 30 degrees, Max Value (upper) 10 degrees
s0

s1

s2

s3

Lower –267

⇒ 7EF5h

⇒ 37h 45h 46h 35h

s4

s5

s6

s7

Upper +89

⇒ 8059h

⇒ 38h 30h 35h 39h

In case of Error

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Parameter Error •Assign illegal parameters.
Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.

Advertising