Vaddio Canon VC-C50i Programmers User Manual

Page 26

Advertising
background image

25

12. Details of Pedestal Control Commands

12.1 Pan Speed Assignment

Pedestal Control Command Type 1

Function

To set running speed of Pan direction.

Command 0050h

Length 3

byte

Range 8~800PPS

(008h~320h)

Parameter

Default Value

800PPS (320h)

Status None
Reference •1LSB of parameter value is equal to 0.1125 degree/s

•The running time of Pan can calculate as under
(Pan position after run) – (Pan position before run)
(Pan running speed)
(refer to 12.27, 12.29 concerning Pan position of pedestal)
Example set Pan running speed 800. In this case, the running time is
approx. 2 seconds from +800 position to –800 position of pedestal.
800{position +90 degree} – (–800){position –90 degree}
800{Pan running speed}

•The command unable to set speed, is Home Position, Pedestal Initialize 1
and Pedestal Initialize 2, total 3 commands.
•Pan running speed can modify by this command during even running Pan.

Format of Control Code

d0 d1 d2 d3 d4 d5 d6 d7 d8

Header Device

Num

Command

Parameter

End

mark

FFh 30h 3Xh 00h 50h p0 p1 p2 EFh

The running speed indicates in 3 figures hexadecimal, and its ASCII code treats as
parameter.
Example: p0 p1 p2
150

⇒ 096h ⇒ 30h 39h 36h

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FFh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Parameter Error •Assigned parameter comes out less than minimum value.

•Assigned parameter comes out more than maximum value.

Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.

Advertising