14.40 Command Termination Notification Setting

System Control Command Type 1

Function

To set command termination notification ON/OFF after command type 2
completion.

Command

0094h

Length 1

byte

0h: OFF (not Notify)

Parameter

Value

1h: ON (Notify)

Status

None

Reference •At the moment of power ON, to OFF by default.

•Command termination notification comes out to effective at the command
after issuing this command.
•See Communication Timing Diagram (3.3), Function of Command
Termination Notification (6)
, Classification by Execution Format (10.2).

Format of Control Code

d0 d1 d2 d3 d4 d5

d6

Header Device

Num

Command Parameter

End

mark

FFh 30h 3Xh 00h 94h p0

EFh

Command termination notification ON/OFF indicates in ASCII code 1 byte.
Example: to notify command termination notification

p0

01h

⇒ 31h

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Parameter Error •In case of assigned parameter except 0h or 1h.
Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.