Vaddio Canon VC-C50i Programmers User Manual

Page 96

Advertising
background image

95

13.34 AGC Gain Assignment

Camera Control Command Type 1

Function

To assign AGC gain.

Command

00A5h

Length

3 byte, including fixed value (37h).

Parameter

Range 00h~FFh

Status

None

Reference •To change AGC magnification.

•To receive command at the moment of exposure mode manual.

Format of Control Code

d0 d1 d2 d3 d4 d5 d6 d7 d8

Header Device

Num

Command

Parameter

End

mark

FFh 30h 3Xh 00h A5h 37h p1 p2 EFh

AGC Gain value indicates in hexadecimal 2 figures and parameter value is its ASCII code.
Example: p1

p2

10

⇒ 0Ah

30h

41h

Answer Format

d0 d1 d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h 3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :

00000000B

⇒ 00h ⇒ 30h 30h

In case of Busy :

00010000B

⇒ 10h ⇒ 31h 30h

In case of Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

In case of Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Condition of Error flag to be set

Busy

•In process of camera initializing operation by Camera Reset
command, etc.
•In status of exposure mode auto.
•In status of AE Lock ON.
•In case of executing Preset Move command.

Parameter Error •In case of assigned parameter out of range.
Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.

Advertising