14.2 Alarm Output ON

System Control Command Type 1

Function

Sets the alarm output (+/– terminal) to closed.

Command

0072h
Length 1

byte

Parameter

Value 1h

Status None
Reference

Format of Control Code

d0 d1

d2

d3 d4 d5 d6

Header Device

Num Command Parameter

End

mark

FFh 30h

3Xh

00h 72h 31h EFh

Answer Format

d0 d1

d2 d3 d4 d5

Header

Device Num

Error Code

End mark

FEh 30h

3Xh e0 e1 EFh

Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
No Error :

00000000B

⇒ 00h ⇒ 30h 30h

Parameter Error :

01010000B

⇒ 50h ⇒ 35h 30h

Mode Error :

10010000B

⇒ 90h ⇒ 39h 30h

Conditions for setting of error flag

Parameter Error •The designated parameter is an invalid value.
Mode Error

•Not in status of Camera ON.
•Not in status of Host Control Mode.