Pwm register descriptions, Pump control register (pmpcon), Pwm register descriptions -3 – Cirrus Logic EP73xx User Manual

Page 109: Pump control register (pmpcon) -3, Table 12-2: pwm pump drive settings -3

Advertising
background image

EP7309/11/12 User’s Manual - DS508UM4

12-3

Copyright Cirrus Logic, Inc. 2003

PWM Interface

1212

12

PWM Register Descriptions

Pump Control Register (PMPCON)

Address:

0x8000.0400, Read / Write

Default:

0x00000000

Bit Descriptions:

Drive 0 from Battery Ratio[0:3]:Control of the Drive 0 PWM pump while the

system is battery powered. Clearing this field turns pump off
while programming value 1-15 will drive pump with the
corresponding duty ratio.

Drive 0 from AC[4:7]: Control of Drive 0 PWM pump while the system is

powered from an external source. Clearing this field turns pump
off while programming value 1-15 will drive pump with the
corresponding duty ratio.

Drive 1 Pump [8:11]:Control of the Drive 1 PWM pump is no conditional upon

power source. Clearing this field turns pump off while
programming value 1-15 will drive pump with the corresponding
duty ratio.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

RSVD

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

RSVD

Drive 1 Pump Ratio

Drive 0 from AC Source Ratio

Drive 0 from Battery Ratio

Table 12-2: PWM Pump Drive Settings

Initial State of Drive 0 or Drive 1

During Power on Reset

Sense of Drive 0 or

Drive 1

Polarity of Bias Voltage

Low

Active high

+ve

High

Active low

-ve

Advertising