Dtc 606- microprocessor failure - cop, Dtc 606- microprocessor failure - cop -164 – JLG 1350SJP Service Manual User Manual

Page 210

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3-164

– JLG Lift –

3121142

DTC 606- Microprocessor Failure - COP

• Engine Control Module

• Check Condition- Key on

• Fault Condition- Internal microprocessor error

• Corrective Action(s) - Illuminate MIL and/or sound audible

warning or illuminate secondary warning lamp, disable
adaptive fueling correction for remainder of key cycle, rec-
ommend power derate 2 and low rev limit to reduce possi-
ble engine damage and/or overspeed condition

• Non-emissions related fault

The ECM has checks that must be satisfied each time an
instruction is executed. Several different things can happen
within the microprocessor that will cause this fault.

If this fault sets, the ECM will reset itself and log the code. The
fault should be configured to never forget and will not self-
erase and will not clear until a technician performs diagnostics
and manually clears the code. This fault should be configured
to set a power derate 2 and low rev limit to reduce possible
engine damage and reduce possibility of an overspeed condi-
tion.

RAM

ECM

Microprocessor