background image

SECTION 4 - BOOM & PLATFORM

3121142

– JLG Lift –

4-19

15.

Tag and disconnect the wiring harness running to the
boom length sensor. Remove all the bolts and washers
securing the sensor, including those that secure the
measuring cable to the telescope cylinder, and remove
the length sensor.

16.

Tag and disconnect the hydraulic hoses from the tele-
scope cylinder. Cap or plug all openings.

17.

Remove the front side, top, and lower wear pads from
the boom base section.

18.

Remove the keepers for the outer mid retract cable
adjustment nuts at the front of the boom base section.

19.

Loosen and remove the outer mid retract cable adjust-
ment nuts.

20.

Remove the adjustment bolt keepers for the outer mid
extend cable adjustment nuts at the rear of the boom.