SECTION 6 - JLG CONTROL SYSTEM

3121142

– JLG Lift –

6-41

OSC AXLE P SW

OP/CL

Displays status of oscillating axle pressure switch. (Displayed if OSCILLATING
AXLE = 1)

SKY WELDER

YES/NO

Displays the status of Sky Welder selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

SKY CUTTER

YES/NO

Displays the status of Sky Cutter selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

SKY GLAZIER

YES/NO

Displays the status of Sky Glazier selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

SKY BRIGHT

YES/NO

Displays the status of Sky Bright selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

PIPE RACKS

YES/NO

Displays the status of Pipe Racks selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

CAMERA MOUNT

YES/NO

Displays the status of Camera Mount selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

LOAD:

Not displayed if LOAD=NO, LENGTH=NO, and ANGLE=NO (machine digits =
0)

LENGTH

OP /CL

Displays measured length, NOTE: Not displayed if MODEL NUMBER = 7 or 8

ANGLE

OP / CL

Displays measured angle, NOTE: Not displayed if MODEL NUMBER = 7 or 8

WEIGHT

XXXX%

Percentage of maximum calibrated weight on the platform. An uncalibrated
load cell will read 1000% Displayed if LOAD is not 0 and LOAD TYPE is 0.

OK/OVERLOADED

Displayed if LOAD is not 0 and LOAD TYPE is 1.

Table 6-5. Machine Diagnostics Parameters

Diagnostics Submenu

(Displayed on Analyzer

1

st

Line)

Parameter (Displayed on

Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description