JLG 1350SJP Service Manual User Manual

Page 507

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121142

– JLG Lift –

6-131

Table 6-13. Load Moment Pin Troubleshooting: Moment Pin Sensor Fault

STEP

FAULT CODE/SYMPTOM

REPAIR

YES

NO

1

8/6 MOMENT PIN SENSOR FAULT The moment pin has
reported a fault flag

Use the Analyzer, scroll to the DIAGNOS-
TICS menu, press ENTER, then scroll to
the MOMENT menu, and press ENTER,
check to see if PIN E FLAGS has any num-
bers on the screen display.

Replace load moment pin &
Perform the Boom Sensor cali-
bration process

Contact JLG Service Dept.

Table 6-14. Load Moment Pin Troubleshooting: New Moment Pin Detected Fault

STEP

FAULT CODE/SYMPTOM

REPAIR

YES

NO

1

8/6 NEW MOMENT PIN DETECTED FAULT A moment pin was
detected on the system different from the one used to cali-
brate the machine.

Perform the Boom Sensor calibration
process to accept the new load moment
pin.

Verify BCS check and review all
faults prior to contacting JLG
Service Dept.

Contact JLG Service Dept.

Advertising
This manual is related to the following products: