MOMENT:

Displayed if MODEL NUMBER = 7 or 8

(LB-IN) ACTUAL

XXXXXXXX

Displays current moment value

(LB-IN)
OVER

XXXXXXXX

Displays current over moment setpoint.

(LB-IN)
UNDER

XXXXXXXX

Displays current under moment setpoint.

CAL PT
UNDER

XXXXXXXX

Displays the under moment value recorded during boom sensor calibration.

CAL PT
WIT YEL

XXXXXXXX

Displays the yellow witness mark moment value recorded during boom sen-
sor calibration.

CAL PT
WIT GRN

XXXXXXXX

Displays the green witness mark moment value recorded during boom sensor
calibration.

CYL PIN
RATIO

X.XXX

Displays the current cylinder moment pin ratio of X and Y forces.

PIN
E FLAGS

0xXXXX

Displays the current error flag status of the cylinder moment pin.

SKY WELDER

YES/NO

Displays the status of Sky Welder selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

SKY CUTTER

YES/NO

Displays the status of Sky Cutter selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

SKY GLAZIER

YES/NO

Displays the status of Sky Glazier selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

SKY BRIGHT

YES/NO

Displays the status of Sky Bright selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

PIPE RACKS

YES/NO

Displays the status of Pipe Racks selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

CAMERA MOUNT

YES/NO

Displays the status of Camera Mount selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

Table 6-5. Machine Diagnostics Parameters

Diagnostics Submenu

(Displayed on Analyzer

1

st

Line)

Parameter (Displayed on

Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description

Advertising