SECTION 6 - JLG CONTROL SYSTEM

3121142

– JLG Lift –

6-93

434

43

4

OIL PRESSURE SHORT TO GROUND

The Oil Pressure Sensor reading
is < 0.1V for more then 5 sec-
onds.

- Deutz engine only.
- Not reported during engine
start.

435

43

5

COOLANT TEMPERATURE SHORT TO GROUND

The Coolant Temperature Sen-
sor reading is < 0.1V.

- Deutz engine only.

437

43

7

ENGINE TROUBLE CODE

Displays engine SPN FMI code.

438

43

8

HIGH ENGINE TEMP

(Ford engine only) The engine
temperature is > 117 C.
(Deutz engine only) The engine
temperature is > 130 C.

- Ford / Deutz engine only.

439

43

9

AIR FILTER BYPASSED

The Air Filter is clogged.

4310

43

10

NO ALTERNATOR OUTPUT

Battery voltage is < 11.5 volts
for more then 15 seconds after
engine start.

4311

43

11

LOW OIL PRESSURE

(Ford engine only) The ECM has
reported a low oil pressure fault.
(Deutz engine only) Oil pressure
is < 8 PSI for more then 10 sec-
onds after engine start.

- Ford / Deutz engine only.

4313

43

13

THROTTLE ACTUATOR FAILURE

The engine RPM is > XXX for
more then XX seconds.

4314

43

14

WRONG ENGINE SELECTED - ECM DETECTED

A ECM was detected with a non-
ECM type engine selected.

4322

43

22

LOSS OF ENGINE SPEED SENSOR

The engine RPM sensor indi-
cates 0 RPM AND the Oil Pressure
Sensor indicates > 8 PSI for
three seconds.

- Diesel engine only.

4323

43

23

SPEED SENSOR READING INVALID SPEED

The engine RPM sensor indi-
cates > 4000 RPM.

- Diesel engine only.

440

44

0

<<< BATTERY SUPPLY >>>

441

44

1

BATTERY VOLTAGE TOO LOW - SYSTEM SHUTDOWN

Battery voltage is < 9V.

442

44

2

BATTERY VOLTAGE TOO HIGH - SYSTEM SHUTDOWN

Battery voltage is > 16V.

445

44

5

BATTERY VOLTAGE LOW

Battery voltage is < 11V for
more then 5 seconds.

450

45

0

<<< CAN CONTROLLED VALVES >>>

451

45

1

MAIN LIFT PVG VALVE - INTERNAL FAULT

The Main Lift PVG Valve has an
internal fault.

- 1250AJP only.

452

45

2

TOWER LIFT PVG VALVE - INTERNAL FAULT

The Tower Lift PVG Valve has an
internal fault.

- 1250AJP only.

453

45

3

TOWER TELESCOPE PVG VALVE - INTERNAL FAULT

The Tower Telescope PVG Valve
has an internal fault.

- 1250AJP only.