SECTION 6 - JLG CONTROL SYSTEM

3121142

– JLG Lift –

6-107

9941

99

41

CHASSIS SENSOR SUPPLY OUT OF RANGE LOW

The Chassis Sensors supply volt-
age is low.

9942

99

42

BLAM BACKUP COMMUNICATIONS LINK FAULTY

The BLAM backup communica-
tions link test was activated at
startup, but no communication
connection established/main-
tained.

- BLAM equipped vehicles only.
-1250

9943

99

43

BLAM BACKUP COMMUNICATIONS LOST - HYDRAULICS SUSPENDED

The BLAM backup communica-
tions link was activated, but no
communication connection
established/maintained.

- BLAM equipped vehicles only.
-1250

9944

99

44

CURRENT FEEDBACK GAINS OUT OF RANGE

The factory set current feedback
gains are out of range.

9945

99

45

CURRENT FEEDBACK CALIBRATION CHECKSUM INCORRECT

The factory set current feedback
checksum is not correct.

9975

99

75

LOAD PIN NOT CALIBRATED

The Load Pin has not been cali-
brated.

-1250

9979

99

79

FUNCTIONS LOCKED OUT - GROUND MODULE SOFTWARE VERSION
IMPROPER

Temporary fault for the telemat-
ics project. The model needs to
be a 600S or 1350S if not this
fault will be generated and Plat-
form controls will be prevented.
This fault was to insure that the
software will only work for
these two models.

Table 6-6. Diagnostic Trouble Code Chart

DTC

Flash

Code

Sequence

Fault Message

Fault Description

Check