Boom sensor calibration position 9 -78 – JLG 1350SJP Service Manual User Manual

Page 454

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-78

– JLG Lift –

3121142

Press Enter. The screen will read:

31.

Telescope to the yellow witness mark (controller will be
close - operator must position the pointer to center line
on decal within 0.25" [6 mm]) for Calibration Position 9.

When the boom is in the proper position, hit Enter. The
screen will read:

When Position 9 calibrating is complete, the screen will
read:

Figure 6-22. Boom Sensor Calibration Position 9