SECTION 6 - JLG CONTROL SYSTEM

3121142

– JLG Lift –

6-17

Table 6-2. Machine Configuration Programming Information - Version P7.X to Present

Configuration Digit

Number

Description

Default

Number

NOTE:

The machine configuration must be completed before any personality settings can be changed. Changing the personal-
ity settings first and then changing the model number of the machine configuration will cause the personality settings
to return to default

MODEL NUMBER:
1

1

2

3

1200S

1250A

1350S

1

ENVELOPE HEIGHT:
2

1

2

3

4

5

6

7

8

9

1350S: 135' MAX

1350S: 125' MAX

1350S: 120' MAX

1350S: 110' MAX

1200S: 120' MAX

1200S: 110' MAX

1250A: 125' MAX

1250A: 100' MAX

1250A: 80' MAX

5

Note: The default settings (bold) will vary depending on the model selection with selection # 5 being the initial default setting.

MARKET:
3

0

1

2

3

4

5

ANSI USA

ANSI EXPORT

CSA

CE

AUSTRALIA

JAPAN

0

ENGINE:
4

1

2

3

DEUTZ F4 TIER1: Deutz BF4M1011 Diesel (Tier 1)

DEUTZ F4 TIER2: Deutz BF4M2011 Diesel (Tier 2)

DEUTZ ECM: Engine Control Module

3