SECTION 6 - JLG CONTROL SYSTEM

3121142

– JLG Lift –

6-49

6.13 CALIBRATING DRIVE

1.

Position the Platform/Ground select switch to the Plat-
form position.

2.

Plug the analyzer into the connector at the base of the
platform control box.

3.

Pull out the Emergency Stop switch and Start the
engine.

4.

The analyzer screen should read:

5.

Use the arrow button to reach ACCESS LEVEL 2. Hit Enter.

6.

Enter the Access Code, 33271.

7.

Use the right Arrow key to reach CALIBRATIONS. Hit
Enter.