15 calibrating platform level, Step 1: setting the platform valve minimums, Calibrating platform level -55 – JLG 1350SJP Service Manual User Manual

Page 431: Step 1: setting the platform valve minimums -55

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121142

– JLG Lift –

6-55

10.

Hit ENTER again. “Cal. Complete” message should
appear

11.

Engine should again return to idle.

12.

Hit ESC should return to “Basket U Crkpt” screen.

13.

Hit RIGHT ARROW to get to the “Basket D Crkpt” screen.
Hit ENTER.

14.

“Calibrate?” prompt should appear. Hit ENTER again.

15.

You will hear engine go to 1800 rpm.

Using UP ARROW, decrease the value until you see the basket
down movement.

Hit ENTER again. “Cal. Complete” message should appear

Engine should again return to idle.

Hit ESC to exit.

Cycle power to the machine.

6.15 CALIBRATING PLATFORM LEVEL

STEP 1: SETTING THE PLATFORM VALVE MINIMUMS

1.

Position the Platform/Ground select switch to the
Ground position.

2.

Plug the analyzer into the connector inside the Ground
control box.

3.

Pull out the Emergency Stop switch and start the
engine.

4.

The analyzer screen should read:

5.

Use the arrow button to reach ACCESS LEVEL 2. Hit Enter.

6.

Enter the Access Code, 33271.

Advertising