Step 2: calibrating the platform level sensors, Step 2: calibrating the platform level sensors -56 – JLG 1350SJP Service Manual User Manual

Page 432

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-56

– JLG Lift –

3121142

7.

Use the arrow button to reach PERSONALITIES adjust
the following personalities. Refer to the Personality
Ranges/Defaults table for proper setting values.

Basket Level Up Min
Basket Level Up Max
Basket Level Down Max
Jib Up Min
Jib Down Min

8.

Recycle EMS.

STEP 2: CALIBRATING THE PLATFORM LEVEL
SENSORS

1.

Position the Platform/Ground select switch to the
Ground position.

2.

Plug the analyzer into the connector inside the Ground
control box.

3.

Pull out the Emergency Stop switch and start the
engine.

4.

Manually level the platform with the switch on the Main
Terminal Box.

5.

The analyzer screen should read:

6.

Use the arrow button to reach ACCESS LEVEL 2. Hit Enter.

7.

Enter the Access Code, 33271.

8.

Use the arrow button to reach CALIBRATIONS menu and
hit ENTER.

9.

Use right arrow go to PLAT. LEVELING screen.