SECTION 6 - JLG CONTROL SYSTEM

6-62

– JLG Lift –

3121142

13.

Hit enter. The number displayed will be the value that
the crack point is set to. The screen will show:

14.

Hit Enter. The screen will read:

15.

Repeat steps 10 thru 12 for the Lift Down function.

16.

After completing all the Tele Calibrations, hit ESC twice
to go back to CALIBRATIONS.

6.17 CALIBRATING TELESCOPE CRACK POINT

1.

Position the Platform/Ground select switch to the Plat-
form position.

2.

Plug the analyzer into the connector at the base of the
platform control box.