Load moment pin troubleshooting, Load moment pin troubleshooting -128 – JLG 1350SJP Service Manual User Manual

Page 504

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-128

– JLG Lift –

3121142

Load Moment Pin Troubleshooting

The following Troubleshooting Charts outline diagnostic mea-
sures to be taken to diagnose problems within the Load
Moment Pin portion of the JLG Control System. If necessary,

refer to Section 4 for information concerning replacement of
the Load Moment Pin.

Table 6-10. Load Moment Pin Troubleshooting: Can Communications Lost

STEP

FAULT CODE/SYMPTOM

REPAIR

YES

NO

1

6/6 CYLINDER LOAD PIN CAN COMMUNICATIONS LOST

Check for correct and tight wire connec-
tions at the deutsch and phoenix con-
nectors of the Load Sensing Pin harness
and perform a continuity check.

Go to step 2

Replace harness. (4922826)

2

Check for loose pins in the potting of the
Boom Length & Angle Module J4 con-
nection.

Replace the BLAM &
Perform the Boom Sen-
sor calibration process.

Go to step 3

3

Inspect the CANbus link ”T” fitting con-
nections at the BLAM & Ground Module.
Are the fittings dry?

Go to step 4

Replace ”T” fitting connector.
(4460945)

4

Inspect the CANbus link ”T” fitting con-
nections at the BLAM & Ground Module.
Perform a continuity check.

Go to step 5

Replace ”T” fitting connector.
(4460945)

5

Check the J1 and J4 plug connections on
the BLAM, make sure the notched plugs
line up with the plug sockets correctly.

Go to step 6

Position plug correctly.

6

Use the Analyzer, scroll – + to the DIAG-
NOSTICS menu, press ENTER, then scroll
to the MOMENT menu, and press ENTER,
check to see i f Actual / Over / Under
moment values are registering on the
screen display.

Go to step 6

Replace the load moment pin. &
Perform the Boom Sensor cali-
bration process.

7

If they are, refer to Figure 6-32.,
Moment Chart fo
r comparable values, if
the values are not close, try boom sen-
sor calibration to see if the values come
within the chart.

If the problem still exists, verify
steps 1-7 again before contact-
ing the JLG Service Dept.

Replace the load moment pin. &
Perform the Boom Sensor cali-
bration process.

Advertising