C14225 | epl mn: max. user data rpdo, C14229 | epl multi-stage node declaration mn, C14231 | epl rpdo – Lenze E94AYCEC User Manual

Page 100: Codes, C14231, 10 parameter reference

Advertising
background image

10

Parameter reference

10.3

Parameters of the communication module for slot MXI2

100

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14225

C14229

C14231

Parameter | Name:

C14225 | EPL MN: Max. user data RPDO

Data type: UNSIGNED_16

Index: 10350 = 0x286E

EPL index: See subcodes

The code defines the reserved user data length of the PRes frames. Each subcode number corresponds to an EPL

node with the same node ID.

The subcode describes the PRes frames received. The value must be within the limits of 36 ... 1490 bytes.

The values are upper limit values for the total size of the PDO mappings which must be defined each one of the

codes

C14231

...

C14240

for PRes frames received.

In the configured state, the values stored for the EPL nodes must be identical to the corresponding

C14072

entries.

C14066

must have an identical value in all EPL nodes of the network.

Setting range

(min. value | unit | max. value)

0

Byte

1490

Subcodes

Lenze setting

Info

EPL index

C14225/1

0 byte

Managing node

0x1F8D.0xF0

C14225/2

0 byte

Diagnostics device

0x1F8D.0xFD

C14225/3

0 byte

router

0x1F8D.0xFE

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14229 | EPL multi-stage node declaration MN

Data type: UNSIGNED_8

Index: 10346 = 0x286A

EPL index: See subcodes

This code indicates in which multiplexed cycle the node is queried. The value entered must not exceed the value in

code

C14074

.

If, for instance, the value "3" is entered in code

C14074

, the multiplexed cycle is repeated every three cycles. If now

the value "3" is entered for one node in C14229/x, it is always queried only in the second cycle of the three

multiplexed cycles.
Setting range

(min. value | unit | max. value)

0

Cycles

255

Subcodes

Lenze setting

Info

EPL index

C14229/1

0 cycles

Managing node

0x1F9B.0xF0

C14229/2

0 cycles

Diagnostics device

0x1F9B.0xFD

C14229/3

0 cycles

router

0x1F9B.0xFE

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14231 | EPL RPDO

Data type: UNSIGNED_64

Index: 10344 = 0x2868

EPL index: See subcodes

EPL RPDO-1
Subcodes

Lenze setting

Info

EPL index

C14231/1

0

EPL RPDO

0x1600.0x01

...

...

...

...

C14231/32

0

EPL RPDO

0x1600.0x20

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising