Technical data

4.1

General data and operating conditions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4

Technical data

4.1

General data and operating conditions

Range

Values

Order designation

E94AYCEC

Communication profile

POWERLINK V2

Communication medium

S/FTP (Screened Foiled Twisted Pair, ISO/IEC 11801 or EN 50173), CAT 5e

Interface for communication

RJ45, Standard Ethernet (according to IEEE 802.3), 100Base-TX (Fast

Ethernet)

Network topology

Tree, star, line

Max. cable length

Number of nodes x 100 m

Cable length between

2 nodes/hubs

max. 100 m

Baud rate

100 Mbps

Type of node

Controlled node

Node addresses

(Node IDs)

1 ... 100

E94AYCEC is controlled node with Lenze module E94AYCEP as

managing node.

1 ... 239

E94AYCEC is Controlled Node with Managing Node of another

manufacturer.

Voltage supply

External supply via separate power supply unit

+: U = 24 V DC (20.4 V ... 28.8 V), I = 140 mA

- : Reference potential for external voltage supply

Conformities, approvals

CE

2004/108/EC, EMC Directive

2006/95/EC, Low-Voltage Directive

EAC

Eurasian conformity

TR CU: Technical Regulations of Customs Union
TP TC 004/2011 (TR CU 004/2011)

About the safety of low voltage equipment
TP TC 020/2011 (TR CU 020/2011)

Electromagnetic compatibility of technical products

UL

UL 508C, Power Conversion Equipment (File-No. E132659)

Servo Drives 9400 hardware manual
Here you can find the ambient conditions and data on the electromagnetic compatibility

(EMC), which also apply to the communication module.