3 settings and displays in the »engineer, Settings and displays in the »engineer, 6commissioning – Lenze E94AYCEC User Manual

Page 37

Advertising
background image

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

37

6

Commissioning

6.3

Settings and displays in the »Engineer«

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3

Settings and displays in the »Engineer«

Setting / display

Description

General

General information on the node type or the synchronisation of the

application

EPL address (project)

Setting of the POWERLINK address (node ID:

C13044

/

C14044

)

You can set the address ’1’ ... ’100’ for the communication module.

Current EPL device address

Display of the current POWERLINK device address (

C13042

/

C14042

)

EPL host name

The DNS-compatible host name (

C13045

/

C14045

) has to be non-

ambiguous within the network domain.

The device name ...

• consists of max. 15 characters ([A ... Z], [a ... z], [0 ... 9], [ - ]);

• starts with a letter;

• ends with a letter or a digit.

EPL IP address

The IP address (

C13000

/

C14000

) is created from the POWERLINK address

(Node ID): 192.168.100.[

C13044

/

C14044

]

Example: 192.168.100.1 = 0xC0.A8.64.01

EPL MAC address

Display of the MAC address (

C13004

/

C14004

)

Open/close advanced

settings

Here, the POWERLINK communication can be reset.