2 powerlink communication data, 1 operating mode "controlled node, Powerlink communication data – Lenze E94AYCEC User Manual

Page 16: Operating mode "co, 4technical data

Advertising
background image

4

Technical data

4.2

POWERLINK communication data

16

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2

POWERLINK communication data

4.2.1

Operating mode "Controlled Node"

• Support of multiplexed CNs
• Support of optional CNs

Range

Values

Jitter synchronisation information

approx. 1 s

Minimum cycle time

Controlled Node: 0.5 ms

Total cycle times

Controlled Node: 0.5 / 1.0 / 2.0 / 3.0 … 20.0 ms

Buffer size

Tx-iso: max. 92 bytes (64 bytes of PDO user data)
Rx-iso: max. 328 Bytes (300 bytes of PDO user data)

Delay times (Controlled Node)

T

Preq

- T

Res

: approx. 1 s

T

SoA

- T

ASnd

: approx. 20 s

Dead times for Managing Node

Between 2 transmission messages: min. 1 s
Between receive and transmit frame: min. 1 s

Frame size

Max. asynchronous frame size (MTU): 1518 bytes

SDO communication method

UDP/IP

Number of RPDOs

Max. 10 channels (max. 300 bytes of PDO user data per channel)

RPDO user data per application (all

RPDOs)

Max. 32 objects (max. 64 bytes)

Number of TPDOs

1 channel (data access of all nodes by broadcasting)

TPDO user data per application

Max. 32 objects (max. 64 bytes)