5

Installation

5.2

Electrical installation

28

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.4

Basic Ethernet Mode

The communication module can be operated in the "Basic Ethernet Mode" for a basic parameter

setting provided that the following applies:

1. Operation of the module with network address  239.

• IP address: 192.168.100.[Node ID]
• see

Node address setting

( 35)

2. Operation with real time POWERLINK must not be carried out.
3. No integration of a Managing Node (node ID  240) into the standard Ethernet network.

Note!

Operation in the "Basic Ethernet Mode" does not permit any real-time communication.