3 diagnostic data, Diagnostic data, 8diagnostics – Lenze E94AYCEC User Manual

Page 52

Advertising
background image

8

Diagnostics

8.3

Diagnostic data

52

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.3

Diagnostic data

Pending diagnostic data are signalled from the controlled node to the managing node by means of

an emergency message.
Errors and warnings in the Servo Drive 9400 and the plugged communication module are sent to the

Managing Node as extended diagnostic messages.
The diagnostic data is visible via the engineering software of the host (PLC).

Bytes

Meaning

Value [hex]

1 ... 6

Diagnostic block header

0x0010 001C 0100

7 ... 8

Alarm type

0x0001 (diagnosis)

9 ... 12

API (Application Programming Interface)

0x0000 0000

13, 14

Slot number

0x0001 / 0x0002

15, 16

Subslot number

0x0001

17 ... 20

Module ID

ID according to module

21 ... 24

Submodule number

ID according to module

25, 26

Alarm specification

0xB000

27, 28

User structure ID

0x0001

29 ... 32

Error code

Reference manual/»Engineer« online help for Servo Drive 9400
Here you will find general information on diagnostics & fault analysis and on error