C14882 | epl reset cycle counter, C14883 | epl response when "dataexchange" is quit, C14885 | epl data rpdo: error response – Lenze E94AYCEC User Manual

Page 105: C14885, C14883, 10 parameter reference

Advertising
background image

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

105

10

Parameter reference

10.3

Parameters of the communication module for slot MXI2

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14882

C14883

C14885

Parameter | Name:

C14882 | EPL reset cycle counter

Data type: UNSIGNED_8

Index: 9693 = 0x25DD

EPL index: not available

The value "1" (TRUE) enables the code to reset the cycle counter (

C14136

).

After reset termination the code automatically assumes the value "0" (FALSE).
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14883 | EPL response when "DataExchange" is quit

Data type: UNSIGNED_8

Index: 9692 = 0x25DC

EPL index: not available

Setting of the response when the "DataExchange" sate is quit.

A change in the monitoring response becomes immediately effective.
Selection list

(Lenze setting printed in bold)

0 No response
1 Trouble
3 Quick stop by trouble
4 Warning Locked
6 Information

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14885 | EPL data RPDO: error response

Data type: UNSIGNED_8

Index: 9690 = 0x25DA

EPL index: not available

The code controls the error response to failing PDO communication with a node. The failure is detected because

expected PDO data are missing.
Selection list

(Lenze setting printed in bold)

Info

0 Process data received

The data received last is continued to be used.

1 Clear process data

The data of all reception PDO channels is set to "0".

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising