C13066 | epl cn: max. user data pres rpdo, C13071 | epl max. pdo user data rpdo preq, C13072 | epl max. pdo user data tpdo pres – Lenze E94AYCEC User Manual

Page 73: C13074 | epl multi-stage cycle timing, 10 parameter reference

Advertising
background image

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

73

10

Parameter reference

10.2

Parameters of the communication module for slot MXI1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13066

C13071

C13072

C13074

Parameter | Name:

C13066 | EPL CN: Max. user data PRes RPDO

Data type: UNSIGNED_16

Index: 11509 = 0x2CF5

EPL index: See subcodes

The code defines the reserved user data length of the PRes telegrams for controlled nodes 1 ... 100. Each subcode

number corresponds to one EPL node with the same node ID. The EPL node must be enabled via code

C13028

.

The subcodes describe the PRes telegrams received. The value must be within the range of 36 ... 1490 bytes.

The values are upper limit values for the entire size of the PDO mappings for received PRes telegrams.

In the configured state, the values stored for the EPL nodes must be identical to the corresponding

C13072

entries.

C13066 must have an identical value in all EPL nodes of the network.
Setting range

(min. value | unit | max. value)

0

Byte

1490

Subcodes

Lenze setting

Info

EPL index

C13066/1

0 byte

EPL CN: max. user data of RPDO

0x1F8D.0x01

...

...

...

...

C13066/100

0 byte

EPL CN: max. user data of RPDO

0x1F8D.0x64

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13071 | EPL Max. PDO user data RPDO PReq

Data type: UNSIGNED_16

Index: 11504 = 0x2CF0

EPL index: 0x1F98.0x04

The code defines the maximum data volume to be received by the controlled node of the PDP mapping for the PReq

telegram to be defined via one of the codes

C13231

...

C13240

.

In the configured state, the value must be identical to the entry for a response valid for the EPL node.

When a Servo Drive 9400 is used, the code as managing node is irrelevant since Servo Drives 9400 as managing

nodes only transmit PDO data via broadcast PRes telegrams (C13071 = 36 bytes).
Setting range

(min. value | unit | max. value)

Lenze setting

0

Byte

1490 36 bytes

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13072 | EPL Max. PDO user data TPDO PRes

Data type: UNSIGNED_16

Index: 11503 = 0x2CEF

EPL index: 0x1F98.0x05

The code defines the maximum PDO data size to be sent by the EPL node for the current network configuration. The

PDO mapping

C13531

can assign data with a total size greater than or equal to C13072.

In the configured state, C13072 must be identical to the entry in

C13066

valid for the EPL node.

Setting range

(min. value | unit | max. value)

Lenze setting

0

Byte

1490 400 bytes

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13074 | EPL multi-stage cycle timing

Data type: UNSIGNED_8

Index: 11501 = 0x2CED

EPL index: 0x1F98.0x07

This code serves to define the maximum number of the multiplexed cycles.

If, e.g., the value "3" is entered, the multiplexed cycle is repeated every three cycles. Within one multiplexed cycle,

the nodes are queried according to the values in code

C13079

. If, e.g., the value "2" is entered for a node in

C13079/

x

, it is always queried only in the second cycle of the three multiplexed cycles.

Setting range

(min. value | unit | max. value)

Lenze setting

0

Cycles

255 0 cycles

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising