C13920 | epl dip switch, 10 parameter reference – Lenze E94AYCEC User Manual

Page 86

Advertising
background image

10

Parameter reference

10.2

Parameters of the communication module for slot MXI1

86

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13920

Parameter | Name:

C13920 | EPL DIP switch

Data type: UNSIGNED_8

Index: 10655 = 0x299F

EPL index: not available

The code outputs the current DIP switch setting of the communication module.

• The switch with the labelling "128" is displayed on the most significant bit, the switch "1" on the least significant

bit.

• The numerical value of C13920 corresponds to the node ID of the communication module.

Node address setting ( 35)

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising